5 ton Capacity Low Pressure Steam Generator

Industrial process steam generators - Reimers Electra Steam, Inc.

Low or high pressure, dry steam is discharged directly into the process, heat exchanger, process heater, or equipment for a quick, efficient operation. The saturated steam from our boilers can be controlled as to pressure which will vary the temperature and BTU transfer of the steam.

Properties of Saturated Steam - Pressure in Bar

Vacuum steam is the general term used for saturated steam at temperatures below 100°C. Example - Boiling Water at 100 o C , 0 bar Atmospheric Pressure At atmospheric pressure (0 bar g, absolute 1 bar ) water boils at 100 o C and 417.51 kJ of energy is required to heat 1 kg of water from 0 o C to evaporating temperature 100 o C .

Steam Generators, Low Pressure Boiler - Ultimate Washer

A steam generator is used as a source of heat for thawing and de-icing aggregates. This low pressure boiler also speeds up the curing process for pre-cast concrete, pipe, pre-stress, block operations, saturating the curing area with steam, uniformly heating the concrete and speeding up the normal process.

Absorption Chillers Overview | Alabama Power

Absorption chillers are available in two types: 1. Single Effect (Stage) Units using low pressure (20 psig or less) as the driving force. These units typically have a COP of 0.7 and require about 18pph per ton of 9 psig steam at the generator flange (after control valve) at ARI standard rating conditions.

150 HP Boiler Models - Steam & Hot Water

150 HP is a very commonly requested size in the boiler business. At 150 HP, you get maximum steam or hot water capacity with a minimally sized footprint, a low overall height for plants with overhead restrictions, and a variety of great American manufacturers who produce this size boiler. 150 HP boilers can be purchased in low pressure (15psi) steam, high pressure (150 - 300psi) steam, hot

Types of High Pressure Boilers | Sciencing

Types of High Pressure Boilers. A boiler is a vessel in which water is heated under pressure and vaporized into steam for a specific purpose. There are several different kinds of boilers, heated by coal, solid fuel, oil or gas. Boilers vary widely in size from small, portable or shop-assembled units to large furnaces

Why Use Low Steam Pressure | Steam Heat Exchanger Basics Part 2

Jan 16, 2017 · If we select a steam-to-water heat exchanger—also called a convertor—at 30 PSIG entering steam pressure, we get a shorter unit than if we select it at 5 PSIG entering steam. There’s slightly more latent heat in higher pressure steam, but the overriding factor comes from the steam temperature. 30 PSIG steam is 274°F while the 5 PSIG steam

Electricity Generation using Steam Turbines

The exhaust steam from the low pressure turbine is condensed to water in the condenser which extracts the latent heat of vaporization from the steam. This causes the volume of the steam to go to zero, reducing the pressure dramatically to near vacuum conditions thus increasing the pressure drop across the turbine enabling the maximum amount of

How to Convert Steam to BTU | Sciencing

For the low-pressure steam typically used in heating systems, that ratio is 1,194 BTUs for every pound of steam the system provides. If your boiler supplies 400 pounds of steam per hour, for example, you would multiply 400 pounds by 1,194 to arrive at a figure of 477,600 BTUs.

Combined Heat and Power Technology Fact Sheet Series

Combined Heat and Power Technology Fact Sheet Series or low pressure steam (15 and the cost for the same capacity to stae unit is ,ton. peration and maintenance

Steam Boiler - Definition, Working Principle, Types, and

The vapor generated may be delivered at low-pressure for the industrial progression work in sugar industries, cotton mills, and for generating steaming water that can be utilized for heat up fixing at much low-force. The capacity of the boiler should have ten liters of water and the working pressure must be 3.4 Kgf/cm2 (kilogram-force).

Specifications

design pressure 15-300 psig 7.5 5 7.5 5 design pressure 301-500 psig 7.5 7.5 7.5 7.5 ELECTRIC FLA, based on 460 V (see note 5) design pressure 15-300 psig design pressure 301-500 psig GAS SUPPLY PRESSURE REQUIRED ATOMIZING AIR REQUIRED (see note 6) Capacity Minimum pressure AIR SUPPLY REQUIRED (FMB - see note 7) WATER SUPPLY REQUIRED HEATING

50 HP Boiler Models - Steam & Hot Water

Although vertical boilers are available at this capacity, most industrial plants elect to go with a horizontal firetube boiler. The horizontal firetube boiler offers a much longer lifespan, safer operation and more stable firing. 50 HP boilers can be purchased in low pressure (15psi) steam, high pressure (150 - 300psi) steam, hot water and high

Steam Generator vs. Steam Boiler | Powerhouse

As water passes through the coil, the heat is transferred from the hot gases which causes the water to convert to steam. The generator design does not utilize a steam drum where the steam of a boiler has a disengagement area from the water in so the use of a steam/water separator to achieve 99.5% steam quality is required.

To produce 1 ton of steam per hour, how much water flow is

The question has already been answered when the generation is for a short duration. However in the real world of steam generation, the water used, even when strictly purified, contains some materials that do not leave the boiler with the steam.

EXCERPTS FROM: ASME BOILER AND PRESSURE VESSEL CODE SECTION I

PG−5.5 The use of austenitic alloy steel is permitted for boiler pressure parts that are steam touched in normal operation. Except as specifically provided in PG−9.1.1, PG−12, and PEB−5.3, the use of such austenitic alloys for boiler pressure parts that are water wetted in normal service is prohibited.7

Steam Generation Thermodynamics 101 | Power Engineering

Main steam is at 2,000 psia, 1,000 F, and has an enthalpy of 1474.1 Btu/lbm. The steam extraction (cold reheat) pressure is 300 psia, which equates (isentropically) to a cold reheat temperature of

Use Low-Grade Waste Steam to Power Absorption Chillers

In a plant where low-pressure steam is currently being exhausted to the atmo- sphere, a mechanical chiller with a COP of 4.0 is used 4,000 hours per year (hr/ yr) to produce an average of 300 tons of refrigeration.

Capital Area System Central Plant Feasibility Study

Capital Area System Central Plant Feasibility Study PREPARED FOR: PREPARED BY: SourceOne, Inc. 7 Penn Plaza, 370 7th Avenue, Suite 704 New York, NY 10001 Phone: (212) 612.7600 www.sourceone‐energy.com

Kangrim Heavy Industries Co., Ltd. - Boilers | LPG Tank

- Steam capacity : 20 ~ 110 ton - Steam Pressure : up to 60 bar (g) MS Series - Complete package unit - Steam capacity : 0.3 ~ 2.2 ton - Top-firing burning system - Water tube / multi tube boiler. MH Series | 1 | 2 | - Marine Horizontal Boiler - Steam capacity : 2.0 ~ 6.0 ton. MV Series

Electric Steam Boilers - Steam - Reimers Electra Steam

The saturated steam from our boilers can be controlled as to pressure, which will vary the temperature and BTU transfer of the steam. We offer a variety of models from 1.5 to 750kW with carbon steel pressure vessels and 1.5 to 120kW in all stainless steel design to match any steam application.

Industrial steam turbines | Steam turbines | Siemens Global

The straight flow turbine solution with power output of up to 250 MW consists of a geared high-pressure steam turbine (backpressure), an intermediate / low-pressure steam turbine (condensing), both driving a generator installed in between.

REGULATOR SIZING - Steam Specialty

steam and other compressible fluids enlarge the delivery pipe size to effect a reasonable flow velocity at the reduced pressure. A tapered transition is recommended. If possible, avoid a sharp turn close to the regulator outlet and a bull-headed tee connection to the low pressure main. 7. Install initial and delivery pressure gauges to indicate

High-Pressure Steam Generators | Sigma Thermal

The NUK® High-Pressure Steam Generator is a closed-looped (hermetically sealed) system that produces steam for high-temperature applications. Therefore, this steam generator is able to produce non-toxic process heat while offering the same advantages of a conventional hot oil system .

boiler, boiler Suppliers and Manufacturers at Alibaba.com

52,919 boiler products are offered for sale by suppliers on Alibaba.com, of which boilers accounts for 7%, boiler parts accounts for 2%, and heating equipment accounts for 1%. A wide variety of boiler options are available to you, such as low pressure, high pressure.

Boiler (power generation) - Wikipedia

A boiler or steam generator is a device used to create steam by applying heat energy to water.Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure (7–2,000 kPa or 1–290 psi) but, at pressures above this, it is more usual to speak of a steam generator.

Air-Cooled Condenser - an overview | ScienceDirect Topics

14.1.2 Air-Cooled Condenser (ACC) (Fig. 14.5) Air is used as cooling medium in condensers located either in deserts or in those areas where substantial quantity of CW is rarely available. Exhaust steam from the turbine is condensed on the inside of the ACC by air flowing past the outside of the tubes.

Water hammer in steam systems: cause and effect

Sep 01, 2006 · Steam pressure: Be careful when the pressure in the steam main is low or zero. Because of the lift after the drip traps, flooding will occur even with some pressure in the steam main. Be especially careful during startup, when boiler goes down and when process loads overwhelm steam capacity. 5. Startup and shutdown: These are critical operations.

Calculator: Saturated Steam Table by Pressure | TLV - A Steam

Online calculator with Saturated Steam Table by Pressure. Includes 53 different calculations. Equations displayed for easy reference.

Boiler Capacity - Engineering ToolBox

W = boiler capacity (Btu/h, kW) h g = enthalpy steam (Btu/lb, kJ/kg) h f = enthalpy condensate (Btu/lb, kJ/kg) m = steam evaporated (lb/h, kg/s) Boiler Horsepower - BHP. The Boiler Horsepower (BHP) is. the amount of energy required to produce 34.5 pounds of steam per hour at a pressure and temperature of 0 Psig and 212 o F, with feedwater at 0

steam boiler weight, steam boiler weight Suppliers and

Alibaba.com offers 488 steam boiler weight products. About 63% of these are Boilers. A wide variety of steam boiler weight options are available to you, such as usage, key selling points, and type.

Power Your Home and Workshop With Steam : 17 Steps

Power Your Home and Workshop With Steam: First Thank you for reading my instructable. This is a work in progress, I will be adding more and more to this instructable on how to build a steam driven turbine and power plant for your home.

Design Guidelines for Humidification Systems

Design Guidelines for Humidification Systems . Use available resources to calculate load correctly. When specifying a humidification system to meet design conditions, expect a maximum humidification load of two to three pounds per hour for every 100 cfm of outside air introduced.

Chiller Tonnage Sizing & Capacity Calculator | Cold Shot Chillers

Calculate tons of cooling capacity Tons = BTU/hr. ÷ 12,000; Oversize the chiller by 20% Ideal Size in Tons = Tons x 1.2; You have the ideal size for your needs; For example, what size chiller is required to cool 40GPM from 70°F to 58°F??T°F = 70°F - 58°F = 12°F; BTU/hr. = 40gpm x 60 x 8.33 x 12°F = 239,904 BTU/hr.

General Engineering Data - Cleaver-Brooks

Table 1 shows capacity of a natural gas line for a given initial pressure with a 5% pressure drop. For example, consider a 500 hp boiler, which requires 20,925 cu.-ft. / hr. A 5 psi initial pressure is available for 100 ft. of pipe. To find the correct pipe size, go to the line for initial gas pressure reading 5 pounds. Now move to the

Boiler Types and Classifications - Wiki - odesie by Tech Transfer

The advantages of a water-tube boiler are a lower unit weight-per-pound of steam generated, less time required to raise steam pressure, a greater flexibility for responding to load changes, and a greater ability to operate at high rates of steam generation.

Combined Heat and Power (CHP) Level 1 Feasibility Analysis

pressure steam (800 psig, 700°F) in a biomass/wood-fired boiler, expanding this steam through a back pressure steam turbine to generate power, and using the low pressure steam (150 psig, 400°F) exhausting from the turbine for process needs (Figure 1). Both boiler/steam turbine CHP options are technically identical—a 110,000 lb/hr stoker

KIDDE FIRE SYSTEMS INTRODUCTION TO LOW PRESSURE CO2

R-404A, aluminum jacket, 17 - 45 ton, R-12 and R-404A Turbine skid package units, steel jacket, 2¾ - 10 ton, R-12 and R-404A • Current Tanks - Fall 2014 - Aluminum jacket units, white finish, R-404A + Horizontal units, front mount refrigeration, 2¾ - 60 ton + Vertical tanks, 6” dip tube, 6 - 30 ton 36

High Pressure Steam Generators | Products & Suppliers

Description: High pressure steam generators as single flame-tube boilers with a performance of up to 17.5 t/h with light oil and 22.8 t/h with natural gas. Based on a furnace heat input of 14.0 MW with light fuel oil and 18.2 MW with natural gas, in accordance with the 97/23/EU